M-THERMO2 u

Part No.: MP-IPET-M-THERMO2-u
8-channel universal thermocouple inputs type J, K, N, R, S, T, E

產品介紹

Features

  • Cold junction compensation per channel
  • Status LED at each measurement channel
  • Measurement data output to CAN
  • Galvanic isolation (inputs, CAN, supply, enclosure)
  • Designed for engine compartment applications
  • Toolless module to module connection
  • Ruggedized and compact modules for harsh environments

Technical Details

Device
Maximum Input Protection Voltage (Channel) ±50 V (indefinitely), ±200 V (short-time, t < 2 ms)
Channel Sampling Rates 1/ 2/ 5/ 10/ min -- 1/ 2/ 5/ 10/ 20/ 50/ 100 Hz
Aggregate Sample Rate 800 Hz
Voltage Supply 9 … 36 VDC
Supply Voltage Thresholds Switch-on 9 ±0.3 VDC / Switch-off 6 ±0.3 VDC
Power Consumption, Typical 0.9 W
Working Temperature Range -40 … 125 °C (-40 … 257 °F)
Storage Temperature Range -55 … 150 °C (-67 … 302 °F)
IP-Code IP 67 (ISO 20653 - 2013)
Relative Humidity 5 … 95 %
Dimensions W106 mm x H30 mm x D57 mm (4.17 in x 1.18 in x 2.26 in)
Weight
295 g (0.65 lb)
Configuration Interface CAN high speed
Data Transfer Rate Software selectable up to 1 Mbit/s (ISO 11898-2)
Input Sockets Miniature TC connector (gold plated)
Galvanic Isolation
Input ↔ Module Power Supply ±100 V (indefinitely), ±500 V (pulse voltage)
Input ↔ CAN ±100 V (indefinitely), ±500 V (pulse voltage)
Input ↔ Enclosure ±100 V (indefinitely), ±500 V (pulse voltage)
Input ↔ Input ±100 V (indefinitely), ±500 V (pulse voltage)
General Channel Properties
A/D Converter 24 bit (Sigma/Delta)
Sensor Break Detection Activation via software settings
Channel LED Available
Flashing Mode of Channel LED Break detection
Flashing Mode of Channel LED During configuration - blinking
Channel Impedance 4.0 MΩ
Hardware Filter (Fixed) 10 Hz, filter type RC-low-pass
Channel Temperature
Measurement Range Temperature Type E (NiCr-CuNi) -60 … 900 °C (-76 … 1652 °F)
Measurement Range Temperature Type J (Fe/CuNi) -50 … 1000 °C (-58 … 1832 °F)
Measurement Range Temperature Type K (NiCr/NiAl) -60 … 1370 °C (-76 … 2498 °F)
Measurement Range Temperature Type N (NiCrSi/NiSi) -50 … 1300 °C (-58 … 2372 °F)
Measurement Range Temperature Type R (Pt13Rh/Pt) -50 … 1760 °C (-58 … 3200 °F)
Measurement Range Temperature Type S (Pt10Rh/Pt) -50 … 1760 °C (-58 … 3200 °F)
Measurement Range Temperature Type T (Cu/CuNi) -200 … 200 °C (-328 … 392 °F)
Accuracy at Ambient Temperature 25 °C ±0.025 % for full measurement range
Drift for Ambient Temperature -40 … 125 °C ±10 ppm/K
Linearization of Sensor Characteristic Line Numerical interpolated
Cold Junction Compensation (CJC) PT100 for each input
Accessories
System Cable  620-561.pdf
System Cable  620-502.pdf
System Cable  620-560.pdf
System Cable  620-567.pdf
System Cable  M-CAN-ABS.pdf
System Cable M-DEF-200.pdf