HV Iso Divider 100 kHz

Part No.: MP-IPET-HV-Iso-Divider-100-kHz
DC high-voltage divider up to 1 kV measuring range

產品介紹

Features

  • Bandwidth up to 100 kHz
  • Reliable voltage measurement on high-voltage DC systems
  • Electrically isolated high-voltage divider
  • Short-circuit current limitation via HV Current Limiter
  • For electric and hybrid vehicle applications
  • Direct connection to SENS modules
  • Approved applications according to CAT I and CAT II
  • Use only together with HV Current Limiter

Technical Details

Device
Maximum Input Protection Voltage (Channel) ±1000 V (indefinitely)
Voltage Supply 15 VDC
Power Consumption, Typical 0.6 W
Working Temperature Range -20 … 70 °C (-4 … 158 °F)
Storage Temperature Range -30 … 70 °C (-22 … 158 °F)
IP-Code IP 67 (ISO 20653 - 2013)
Relative Humidity 5 … 95 %
Dimensions W126 mm x H50 mm x D25 mm (4.96 in x 1.97 in x 0.98 in)
Weight 120 g (0.26 lb)
Input Sockets 4 mm saftey banana plugs
Galvanic Isolation
Test Voltage 3536 VAC @ 50 Hz (sine wave)
Application According to CAT I ±1000 VDC
Application According to CAT II 600 VAC @ 50 … 60 Hz (sine wave)
Input HV
Measurement Range ±1000 VDC
Accuracy at Ambient Temperature 25 °C ±0.20 %
Accuracy at Ambient Temperature -20 … 70 °C ±0.50 %
Channel Impedance 11 MΩ / 22 pFF (with HV Current Limiter)
Cut-off Frequency 100 kHz (max. input cable lengh 1 m)
Hardware Filter Types Bessel (6-pole)
Channel LED No
Accessories
System Cable  620-661.pdf
System Cable  620-640.pdf
Input Cable  620-044.pdf