Connect Laptop to ControlNet Network
Configuration on the Move
Rockwell Technology Partner Product
Easy Setup
| Electric Properties | Enclosure type rating | Meets IP30 |
|---|---|---|
| Supply voltage | 5.25 volts DC | |
| Supply current | 225 mA | |
| Isolation voltage | 30 Volts continuous, basic insulation type | |
| Wiring category | Type tested at 500 V AC for 60 seconds, ControlNet to USB 2 - on communication port | |
| ControlNet current value | 70 mA@ 24 volts | |
| Operating temperature |
IEC 60068-2-1 (Test Ad, Operating Cold)
IEC 60068-2-2 (Test Bd, Operating Dry Heat)
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
|
0....55 degrees C (32....131 degrees F) |
| Certifications |
c-UL-us, CE, RCM KCC,
CI (ControlNet International conformance tested to ControlNet specification)
|
|
| USB LED | Green | cable configured, but no network traffic present |
| Flashing green | unable to transfer data | |
| Off | unable to transfer data | |
| Module status LED | Green | cable is operating normally |
| Off | no power to cable | |
| Flashing green | normal, operating, online, with no connection | |
| Red | cable has an unrecoverable fault and might need to be replaced | |
| Flashing red/green | the cable is performing a self test | |
| Flashing red | the cable has an unrecoverable fault | |
| CNET LED | Off | not on a network |
| Red | network interface fault | |
| Flashing red/green | invalid network configuration (for example, a MAC ID above UMAX) | |
| Flashing red | duplicate node detected, link fault, no MAC frames received | |
| Flashing green | temporary channel error, listen only | |
| Green | normal operation. MAC frame received without error. |