Part No.: MPHS-CIFX-104C-CO|F+M (+Master Licence)
MPHS-CIFX-104C-CO|F (Slave only)
CANopen-Master/ Slave: Communciation for PC-based Automation
The cifX PC card family is the unified standard supporting all Real-Time Ethernet and Fieldbus systems for PC based automation.
The protocol stack is executed autonomously on the PC card and process data exchange with the host is done via Dual-Port-Memory or DMA (Direct Memory Access). Thanks to the common Hilscher Platform Strategy all PC cards use the same driver and tools - independent of protocol and card format. Thanks to the netX technology there is exactly one hardware needed for the realization of all Real-Time Ethernet protocols. A change of the communication protocol is done by just loading a different firmware.
Always the right solution! Different cable lengths, M-12 connectors, additional NVRAM, extended temperature range, 2-channel cards or detached network interfaces – numerous hardware options always offer the right solution for your application. On top, a wide range of device drivers and a C-Toolkit, free of charge, are available.
The PC based automation is evolving and the Hilscher cifX PC card family keeps the pace. With continuous expansion for new standards, protocols and formats, as M.2, mini PCIe halfsize or CC-Link IE Field, customers are always prepared for new market demands.
Product | Product Name | CIFX 104C-COF |
---|---|---|
Part Number | 1270.501 | |
Brief Description | PC Card cifX PCI-104 CANopen Master or Slave - with cable connector fieldbus for CANopen assembly interface (AIFX-CO) - and cable connector DIAG for diagnostic assembly interface (AIFX-DIAG) | |
Function |
Communication Interface with PCI-104 and fieldbus interface CANopen
|
|
Communication Controller | Type: netX 100 | |
Integrated Memory |
RAM: 8 MB SDRAM
FLASH: 4 MB serial Flash EPROM
|
|
Power Supply |
Supply voltage: +5 V DC ±5 % or +3,3 V DC ±5 %
Maximum current (typically): 500 mA (at 5 V), 650 mA (at 3,3 V)
Connector: via PCI-104 Bus
|
|
System Interface |
Bus type: PCI-104
Data access: DPM or DMA (Direct Memory Access)
Dual-port memory size: 64 KByte
Data width: 32-Bit
Transmission rate: 33 MHz
|
|
Communication Interface |
Communication standard: CANopen
Interface type: ISO-11898, optically isolated
Connector: Cable Connector DIAG X303 (X3) (JST 12FMN-SMT-A-TF(LF)(SN), pitch 1,0 mm) to connect a CANopen Assembly Interface AIFX-CO
|
|
Diagnostic Interface | Connector: Cable Connector DIAG X303 (X3) (JST 12FMN-SMT-A-TF(LF)(SN), pitch 1,0 mm) to connect a Diagnostic Assembly Interface AIFX-DIAG | |
Displays | LED display: SYS, System status LED | |
Operating Element | Rotary Switch PCI-104 Slot Number: To set the PCI-104 slot number | |
Permitted Ambient Conditions |
Operating temperature range: –20 °C ... +70 °C (Air flow during measurment: 0,5 m/s)
Storage temperature range: –10 °C ... +70 °C
Humidity: 10 % … 95 % relative humidity, no condensation permitted
Environment: For UL compliant usage: The device must be used in a pollution degree 2 environment.
|
|
Device |
Dimensions (L x W x H): 97 x 91 x 24 mm
Mounting/Installation: PCI-104 Slot (supply voltage 5 V or 3.3 V, signaling voltage 5 V or 3.3 V)
|
|
Conformity | RoHS: Yes | |
UL Certification |
UL: The device is certified according to UL 508
UL file: UL-File-Nr. E221530
|
|
Conformance with EMC Directives |
CE sign: Yes
Emission: EN 55011:2009 + A1:2010, CISPR 11:2009, Class A (Radio disturbance characteristics - Limits and methods of measurement)
Immunity:
|