usbLink CN

Part No.: MPST-1784-U2CN
USB to ControlNet Interface, Cable and Connectors

Product Description

Description


usbLink CN

USB to ControlNet Interface, Cable and Connectors

  • usbLink CN replaces the Allen-Bradley 1784-U2CN interface
  • USB 2.0 for laptop connection and RJ45 for ControlNet connection
  • Use with RSLinx and RSNetWorx to configure the network and field devices

 

Overview

Connect Laptop to ControlNet Network

  • Use RSLinx version 2.51 or later
  • Use RSNetWorx for ControlNet to communicate with devices via RSLinx
  • USB 2.0 connector for connection to laptop or PC
  • RJ-45 connector for connection to NAP (network access port) of a ControlNet network enabled device

Configuration on the Move

  • Use usbLink CN when you travel to sites with ControlNet as a quick and easy way to temporarily connect and configure networks and devices with a laptop
  • Use RSLinx to scan/browse a ControlNet network
  • Use RSNetWorx for configuring devices, configuring the network, read diagnostics and status, and troubleshooting
  • Use RSStudio (RSLogix) for PLC programming

Rockwell Technology Partner Product

  • The usbLink CN replaces the Allen Bradley 1784-U2CN
  • Softing is a Rockwell Technology Partner and the usbLink CN is an approved product in the Technology Partner Program

Easy Setup

  • Load RSLinx software and the usbLink CN device driver if using RSLinx versions before v2.54. RSLinx v2.54 and later contains the necessary device driver
  • Use the rotary switches to set the module node address (1 - 99)
  • Insert USB end of the cable to laptop
  • Insert RJ-45 end of cable into a ControlNet enabled access port (NAP)
  • LEDs indicate USB status, module status, and ControlNet network status

Technical Data


Electric Properties Enclosure type rating Meets IP30
Supply voltage 5.25 volts DC
Supply current 225 mA
Isolation voltage 30 Volts continuous, basic insulation type
Wiring category Type tested at 500 V AC for 60 seconds, ControlNet to USB 2 - on communication port
ControlNet current value 70 mA@ 24 volts
Operating temperature
IEC 60068-2-1 (Test Ad, Operating Cold)
IEC 60068-2-2 (Test Bd, Operating Dry Heat)
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
0....55 degrees C (32....131 degrees F)
Certifications
c-UL-us, CE, RCM KCC,
CI (ControlNet International conformance tested to ControlNet specification)
USB LED Green cable configured, but no network traffic present
Flashing green network traffic is present
Off unable to transfer data
Module status LED Green cable is operating normally
Off no power to cable
Flashing green normal, operating, online, with no connection
Red cable has an unrecoverable fault and might need to be replaced
Flashing red/green the cable is performing a self test
Flashing red the cable has an unrecoverable fault
CNET LED Off not on a network
Red network interface fault
Flashing red/green invalid network configuration (for example, a MAC ID above UMAX)
Flashing red duplicate node detected, link fault, no MAC frames received
Flashing green temporary channel error, listen only
Green normal operation. MAC frame received without error.

Order Information


Scope of Delivery
Hardware SOFTING 1784-U2CN Interface module
Documentation User Guide
Order Numbers
SOFTING 1784-U2CN USB to RJ-45 Interface module, cable, connectors for connecting laptop to ControlNet enabled device

Note:

1. Prices and specifications are subject to change without notice.
2. EOL products will not be notified separately.
3. Product images are for reference only. Actual products may vary depending on the version or specifications.
4. Product information, specifications, and availability are subject to confirmation at the time of order.