smartLink SW-HT

Part No.: MPST-smartLink-SW-HT
Access to HART devices connected to Allen-Bradley, Siemens, Schneider Electric or R.Stahl controllers and remote I/Os for Emerson’s AMS and FDT.

Product Description

Description


HART Multiplexer Software to Access Configuration & Diagnostics Data

Interface software to access HART devices from Emerson’s AMS and other HART-IP enabled applications.

smartLink SW-HT is a HART multiplexer that provides a simple and fast access to HART field devices without additional hardware. It is a software interface solution for HART devices connected to Allen-Bradley, Siemens,  Schneider Electric, R.Stahl, Turck or Altus HART IO modules. The integrated HART-IP server enables transparent access to the HART devices.

smartLink SW-HT enables remote asset management, device configuration and monitoring. It allows to access device identification, health, diagnostics, and process data.


 

Overview

Access HART devices without additional Hardware

  • Use the existing infrastructure to access the HART devices
  • No additional cost for HART multiplexer hardware
  • No installation and maintenance of additional Hardware
  • Optional routing of the communication to the Allen-Bradley and Schneider Electric remote I/Os through the controller

Highly scalable business model

  • Pay only for the HART devices connected with smartLink SW-HT
  • Scalable license model based on the number of HART devices to access
  • Try it with 1 HART device for free

Transparent HART communication

  • The HART commands sent to the HART-IP server are forwarded to the HART devices
  • No limitation on the supported HART commands
  • Uses the open HART-IP protocol
  • FDT Communication DTM for the integration into FDT applications

Easy deployment

  • Easy to use on a Windows workstation with the VM deliverable
  • Web based configuration software is included in the container

Technical Data


Supported Controller and Remote IOs Generally, smartLink works independent from the controller. The controllers listed here are supported with their direct HART IO modules.
Allen-Bradley:
1756 ControlLogix: 5580, 5570 and older series, 1734 Point I/O, 1794 Flex I/O, 5094 Flex 5000 I/O, 1719 Ex-I/O, 1715 Redundant I/O
CIP routing:
CIP routing can be used with all controllers and communication modules supporting it, including 1756 redundant controllers. For 5069 controllers with dual IP interfaces CIP routing between A1 and A2 is supported.
Siemens:
ET 200iSP: PROFINET IM152-1PN 6ES7152-1BA00-0AB0 (redundant)
ET 200SP: PROFINET IM155-6PN (High Feature) 6ES7155-6AU01-0CN0,
     PROFINET IM 155-6 PN/3 6ES7155-6AU30-0CN0 (redundant),
     PROFINET IM 155-6 PN R1 6ES7155-6AU00-0HM0 (redundant)
ET 200SP HA: PROFINET IM155-6PN 6DL1155-6AU00-0PM0 (redundant)
ET 200M: PROFINET IM153-4 PN (High Feature) 6ES7153-4BA00-0XB0
CFU HART: 6ES7655-5PX41-1XX0
Schneider Electric:
M580 controller or X80 EIO Drop adapter (BMECRA31210)
R.Stahl:
IS1+ Ex Zone 1 (9442/32-10-00, 9441/12-00-00) and Ex Zone 2 (9442/35-10-00)
Turck:
excom GEN-3G (100004545) and GEN-N (100000129)
Altus:
Nexto controllers with Nexto NX5210 PROFIBUS Remote IO or Pronto PO5064/PO5065 PROFIBUS Remote IO
Supported HART IO Modules
Allen-Bradley:
1756 ControlLogix: 1756-IF8H, 1756-IF8HK, 1756-IF16H, 1756-IF16HK, 1756-IF8IH, 1756-IF16IH, 1756-IF16IHK, 1756-OF8H, 1756-OF8HK, 1756-OF8IH, 1756-OF8IHK
1734 Point I/O: 1734sc-IE2CH, 1734sc-IE4CH, 1734sc-OE2CIH 
1794 Flex I/O: 1794-IE8H, 1794-IF8IH, 1794-IF8IHNFXT, 1794-OE8H, 1794-OF8IH
5094 Flex 5000 I/O: 5094-IF8IH, 5094-IF8IHXT,5094-OF8IH, 5094-OF8IHXT, 5094-IF4IHS
1719 Ex-I/O: 1719-IF4HB, 1719-CF4H
1715 Redundant I/O: 1715-IF16, 1715-OF8I
Siemens:
ET 200iSP: 6ES7134-7TD00-0AB0, 6ES7134-7TD50-0AB0, 6ES7135-7TD00-0AB0, 6ES7138-7FA00-0AB0
ET 200SP: 6ES7134-6TD00-0CA1, 6ES7135-6TD00-0CA1
ET 200SP HA: 6DL1133-6EW00-0PH1, 6DL1133-6EW00-0EH1, 6DL1134-6TH00-0PH1, 6DL1134-6UD00-0PK0, 6DL1134-6TB00-0HX1, 6DL1135-6TF00-0PH1, 6DL1135-6UD00-0PK0, 6DL1135-6TB00-0HX1, 6DL1135-6TF00-0EH1, 6DL1136-6AA00-0PH1, with optional module redundancy
ET 200M: 6ES7331-7TF01-0AB0, 6ES7332-8TF01-0AB0, 6ES7331-7TB10-0AB0, 6ES7332-5TB10-0AB0, 6ES7336-4GE00-0AB0
Schneider Electric:
M580: BMEAHI0812, BMEAHO0412
R.Stahl:
9461/12-08-11, 9466/12-08-11, 9468/32-08-10, 9468/32-08-11, 9468/33-08-10, 9469/35-08-12
Turck:
AIH401EX, AOH401EX, AIH401-N, AOH401-N
Altus:
Nexto: NX6014, NX6134
Pronto: PO1114, PO2134
Supported HART-IP Client Applications
Emerson AMS Device Manager >= V14
Honeywell Experion PKS Field Device Manager (FDM) >= R540.2
Softing smartLink DTM >= V1.10
Communication Protocols HART-IP
Tested with
Emerson AMS Device Manager V14.1.1, V14.5 (HART-IP application)
Honeywell Experion PKS Field Device Manager (FDM) R540.2 (HART-IP application)
PACTware, Endress + Hauser FieldCare (FDT applications)
Docker
Minimum Hardware Requirements
Docker Container: 200 MB free disk space, 500 MB RAM
Virtual Machine:
VMware 3 GB free disk space, 2 GB RAM
Hyper-V 5 GB free disk space, 2 GB RAM
Licensing Node locked license for Docker container

Order Information


Scope of Delivery
Software smartLink SW-HT as Virtual machine or Docker container – additionally available via Docker Hub
Documentation User Guide
Order Numbers
For free smartLink SW-HT, Software HART multiplexer. Try it with 1 HART device
LRA-MM-027002 smartPlus HT, License for access to one HART device
Additional Products and Services
LRA-MM-020670 DevComDroid HART – Android application for HART device communication
LRA-MM-020672 DevDom.iOS HART – Apple iOS application for HART device communication
LRA-MM-020671 DevCom2000 HART – Windows application for HART device communication
DBA-KM-020410 mobiLink – Mobile HART interface

Note:

1. Prices and specifications are subject to change without notice.
2. EOL products will not be notified separately.
3. Product images are for reference only. Actual products may vary depending on the version or specifications.
4. Product information, specifications, and availability are subject to confirmation at the time of order.