mobiLink

Part No.: MPST-mobiLink
Mobile interface for HART, FOUNDATION fieldbus, PROFIBUS PA

Product Description

Description


Mobile & USB Interface for HART, FOUNDATION fieldbus, PROFIBUS PA

Bluetooth and USB Interface for commissioning parameterization & maintenance for field devices

mobiLink is a mobile and a USB interface for HART, FOUNDATION Fieldbus and PROFIBUS PA.

The Bluetooth and battery operation enables it to be used with handheld host devices such as tablets and smartphones. 

mobiLink can be used in a variety of applications since it is compatible with FDT Frame applications and other major engineering tools. Additionally, It is suited for harsh environments (approved by IECEx and EX for Zone 1).

Similar Solution:

  • mobiLink Power: Single USB interface for PROFIBUS PA, HART, FOUNDATION fieldbus with integrated power supply for field devices

 

Overview

Multi protocol operation

  • HART Master, Foundation fieldbus Host and PROFIBUS PA Master included in one device
  • Temporary attachment to fieldbus segments or HART loops for individual interaction with field devices
  • Fully compliant protocol implementations allow for interference-free access to running plants

Host communication via Bluetooth or USB

  • Built-in batteries and Bluetooth communication enable use of handheld host devices like smart phones and tablets
  • USB interface for bench host operation

Support of FDT Frame Applications and major Engineering Tools

  • PACTware FDT Frame Application and HART Communication DTM included
  • Communication DTM for Foundation fieldbus and PROFIBUS PA (optional)
  • Foundation fieldbus configuration tool (optional)
  • Application Program Interface for integration into Engineering Systems

Suitable for use in hazardous areas

  • IECEx and EX approval for Zone 1, NEC500 Cl. Div.1
  • Suitable for connection to intrinsically safe circuits
  • Suited for harsh environment

Technical Data


Supported Applications
  • Endress + Hauser FieldCare for HART, PROFIBUS PA and FF devices
  • Pactware for HART, PROFIBUS PA and FF devices
  • ProComSol DevCom for HART and FF devices
  • AMS Device Manager for HART devices
User Interface
Controls
Status LEDs
Power on/off button, Bluetooth pairing button
FIELDBUS (Fieldbus mode), HART (HART mode), Bluetooth (Pairing/Bluetooth active), Low battery, Power on
Interfaces and Connectors USB
Speed: USB 2.0 Full Speed, Connector: USB Type C
Electrical: Non intrinsically safe. Do not use inside hazardous areas. 5 V, 100 mA. Um = 253 V
Bluetooth Dual Mode (BT Classic and BLE), 2.4 - 2.478 GHz, Output Power: +8 dBm (maximum)
Fieldbus
Connection: 4 mm banana type jacks (red/black), polarity has to be observed
Physical Layer: according to IEC 61158-2, Type 1: 31.25 Kbit/s, voltage mode
Nominal input current (Fieldbus):
10 mA in Bluetooth and regular USB mode
18 mA (with fieldbus voltage > 9,5V) for increased battery life time in USB mode (controlled by application)
Fieldbus Terminator: No built-in fieldbus terminator
HART
Connection: 4 mm banana type jacks (red/black)
Physical Layer: HART FSK compliant modem
Operation in Hazardous Areas Intrinsic Safety EX ia IIB, Ui = 30 V or FISCO field device
Parameters Isolation: 1500 VDC between USB and Fieldbus, 1500 VDC between USB and HART
IECEx Ex ib [ia Gb] IIB (HW version 1.00), IIC (HW version 1.01) T4 Gb; Ex ib [ia Da] IIIC T100°C Db
ATEX II 2G Ex ib [ia Ga] IIB (HW version 1.00), IIC (HW version 1.01) T4 Gb; II 2D Ex ib [ia Da] IIIC T100°C Db
Physical Properties Dimensions (L x W x D) 175 mm x 74 mm x 32 mm
Weight 330 g (incl. Batteries)
Power Supply
Battery: 3 * Alkaline, IEC-LR6, nominal voltage 1,5 V
For use in hazardous area: Energizer E91 or Duracell Procell MN1500.
With batteries of other types or manufacturers certification is void.
Fieldbus interface (Medium Attachment Unit) powered by fieldbus.
Operating Temperature -20°C .. +50°C
Storage Store batteries in a dry place at normal room temperature.
Relative Humidity < 95% rH non condensing
Protection Class IP 54 (if USB port covered with cap)
Certifications Ex ATEX, IECEx, FM, PCEC, KC, PESO
EMC/Radio CE, FCC, SRRC, ETA, MIC, KC, TRA
ROHS UAE

Order Information


Scope of Delivery
Hardware mobiLink, USB cable, fieldbus cable set with clips, 3 * Alkaline IEC-LRC6
Software
mobiLink Manager, PACTware, Communication DTM for HART, Foundation Fieldbus, PROFIBUS PA, Yokogawa Interface and FDI CommServers
(for Foundation Fieldbus and PROFIBUS PA optional license required)
Documentation User Guide
Order Numbers
DBA-KM-020410 mobiLink with embedded HART Master , including accessories
LRA-KK-021973 linkPlus FF – License to activate Foundation Fieldbus
LRA-LL-021974 linkPlus PA – License to activate PROFIBUS PA
Additional products and services
LRA-MM-020670 DevComDroid HART – Android application for HART device communication
LRA-MM-020671 DevCom2000 HART – Windows application for HART device communication
LRA-KK-020673
DevComFF.Win – Windows application for FF device communication
LRA-MM-020672 DevCom.iOS HART – iOS application for HART device communication

Note:

1. Prices and specifications are subject to change without notice.
2. EOL products will not be notified separately.
3. Product images are for reference only. Actual products may vary depending on the version or specifications.
4. Product information, specifications, and availability are subject to confirmation at the time of order.