M-THERMO 16

Part No.: MP-IPET-M-THERMO-16
16-channel thermocouple inputs type K (NiCr/NiAl)

產品介紹

Features

  • 4 PT100 for cold junction compensation
  • Status LED at each measurement channel
  • Measurement data output to CAN
  • Galvanic isolation (inputs, CAN, supply, enclosure)
  • Designed for engine compartment applications
  • Toolless module to module connection
  • Ruggedized and compact modules for harsh environments

Technical Details

Device
Maximum Input Protection Voltage (Channel) ±50 V (indefinitely), ±200 V (short-time, t < 2 ms)
Channel Sampling Rates 1/ 2/ 5/ 10/ min -- 1/ 2/ 5/ 10/ 20 Hz
Aggregate Sample Rate 320 Hz
Voltage Supply 9 … 36 VDC
Supply Voltage Thresholds Switch-on 9 ±0.3 VDC / Switch-off 6 ±0.3 VDC
Power Consumption, Typical 1.2 W
Working Temperature Range -40 … 125 °C (-40 … 257 °F)
Storage Temperature Range -55 … 150 °C (-67 … 302 °F)
IP-Code IP 67 (ISO 20653 - 2013)
Relative Humidity 5 … 95 %
Dimensions W204 mm x H41 mm x D55 mm (8.03 in x 1.61 in x 2.17 in)
Weight 630 g (0.69 lb)
Configuration Interface CAN high speed
Data Transfer Rate Software selectable up to 1 Mbit/s (ISO11898-2)
Input Sockets Miniature TC connector green (DIN IEC 584)
Input Sockets Miniature TC connector yellow (ANSI MC 96.1)
Galvanic Isolation
Input ↔ Module Power Supply ±100 V (indefinitely), ±200 V (short-time, t < 2 ms)
Input ↔ CAN ±100 V (indefinitely), ±200 V (short-time, t < 2 ms)
Input ↔ Enclosure ±100 V (indefinitely), ±200 V (short-time, t < 2 ms)
Input ↔ Input ±100 V (indefinitely), ±200 V (short-time, t < 2 ms)
General Channel Properties
A/D Converter 16 bit / SAR (successive approximation register)
Sensor Break Detection Activation via software settings
Channel LED Available
Flashing Mode of Channel LED Break detection - permanent active
Flashing Mode of Channel LED During configuration - blinking
Channel Impedance 10 MΩ (inactive sensor break detection)
Channel Impedance 1 MΩ (active sensor break detection)
Hardware Filter (Fixed)
1 Hz, filter type RC-low-pass
Channel Temperature
Measurement Range Temperature Type K (NiCr/NiAl) -60 … 1370 °C (-76 … 2498 °F)
Accuracy at Ambient Temperature 25 °C ±0.025 % (typical)
Accuracy at Ambient Temperature 25 °C ±0.035 % in the range -60 … 1000 °C (-76 … 1832 °F)
Accuracy at Ambient Temperature 25 °C ±0.035 % ±2 K in the range 1000 … 1370 °C (1832 … 2498 °F)
Drift for Ambient Temperature -40 … 85 °C ±20 ppm/K
Drift for Ambient Temperature 85 … 120 °C ±30 ppm/K
Linearization of Sensor Characteristic Line Numerical interpolated
Cold Junction Compensation (CJC) 4 PT100 (1 for 4 channels)
Accessories
System Cable  620-561.pdf
System Cable  620-502.pdf
System Cable  620-560.pdf
System Cable  620-567.pdf
System Cable  M-CAN-ABS.pdf
System Cable  M-DEF-200.pdf