COMX 10CN-CCS

Part No.: MPHS-COMX-10CN-CCS
CC-Link Slave: The module for all communication tasks

產品介紹

Features

  • Complete slave interface with network connector onboard
  • Host connection via dual-port memory or SPI
  • Allows one baseboard design for all networks

Product Description

The comX communication module has been designed to be integrated into automation devices e.g. robot controllers, PLCs or drives to add a network interface. All communication tasks are executed autonomously within the module - irrespective of the processor of the target device.

Process data is exchanged via a Dual-Port-Memory which is accessed either by an 8-/16-bit bus interface or a fast 50 MHz SPI interface.

comX supports all major Real-Time Ethernet protocols as Master or Slave and covers all network-specific demands in just one single module. To support a line topology, the module is equipped with two Ethernet ports. The communication protocol can be changed simply and reliably by loading the appropriate firmware and a software license for masters.


Technical Details

Product Part Number 1532.740
Brief Description Communication Module CC-Link Slave
Communication
Controller
netX: netX 10
Integrated
Memory
FLASH: 4 MB serial Flash
Power
Supply
Supply voltage: +3.3 V DC ± 5 %
Typical/maximum current: approx. 225 mA/260 mA (at 3.3 V)
Typical power consumption: approx.0,75 W
Power connector: via system bus connector X1
System
Interface
Type: Parallel or serial dual-port memory interface
Connector: 50-pin SMT, female connector
Pin distance: 1.27 mm
Dual-port memory size: 16 KByte (lowest 8 KByte used by firmware)
Data width: 8/16 bit
Serial dual-port memory interface: SPI Slave, mode 3
Baud rate: max. 50 MHz
Communication
Interface
Communication standard: CC-Link Slave
Interface type: RS-485, potential-free
Connector: 30-pin SMT connector, female, grid distance 1.27 mm, matching with plug type SAMTEC TFM-115-02-S-D–A
Display LED display:
  • Signals at X2 for SYS System Status, green: RUN, yellow: RDY
  • Signals at X2 L RUN/L ERR Communication status, green: L RUN, red: L ERR
Operating
Elements
Network address: 2 rotary switches for address
Environment Ambient temperature range for operation: 0 °C ... +55 °C (Air flow during measurment: 0,5 m/s)
Ambient temperature range for storage: -10 °C … +70 °C
Humidity range: 10 % … 95 % relative humidity (non-condensing)
Device Dimensions (L x W x H): 70 mm x 30 mm x 21.5 mm
Weight: approx. 35 g ... 40 g
Mounting: using screwable metal bolts, according to comX Design Guide
Configuration Configuration software: SYCON.net
Conformity RoHS: yes
Conformance
with EMC
Directives
CE sign: yes

Emission: EN 61000-6-4

Immunity: EN 61000-6-2

Electrostatic discharge (ESD) according to EN 61000-4-2 (Air discharge method): EN 61000-4-2: ± 8 kV, Criterion B

Electrostatic discharge (ESD) according to EN 61000-4-2 (Contact discharge method): EN 61000-4-2: ± 6 kV, Criterion B

Fast transient interferences (Burst) according to EN 61000-4-4: EN 61000-4-4: ± 2.5 kV, Criterion B (Communication lines, shielded)

Surge voltage according to EN 61000-4-5 (Communication and data lines): EN 61000-4-5: 1 kV, Criterion A (Communication lines, shielded)

 

Ordering Information

  • COMX 10CN-CCS (1562.740/CCS) - Communication Module SPI -CC-Link Slave