Part No.: MPHS-CIFX-70E-CO|MR+M (+Master Licence)
MPHS-CIFX-70E-CO|MR (Slave only)
CANopen-Master/ Slave: Communciation for PC-based Automation
The cifX PC card family offers the user a unified standard supporting all Real-Time Ethernet and fieldbus systems for PC-based automation.
The entire protocol stack is processed on the PC card. The process data exchange with the host is executed via Dual-Port-Memory or DMA (Direct Memory Access). Thanks to the uniform Hilscher platform strategy, all PC cards use the same drivers and tools, irrespective of protocol and card format. Communication protocols can be changed easily by loading the appropriate firmware. A rotary switch allows a simple and reliable slot assignment of the PCI and PCI Express card types. Moreover, special types are available, e.g. with integrated NVRAM, 2-channel cards or detached network interface.
A complete software package is always included within the scope of delivery. This package consists of an FDT-based configuration tool (IEC standard) for all products and networks, loadable firmware, documentation, and a driver tool kit.
Due to the Hilscher network controller netX, a 10-years delivery guarantee is granted.
Product | Product Name | CIFX 70E-COMR |
---|---|---|
Part Number | 1259.503 | |
Brief Description | PC Card cifX Low Profile PCI Express CANopen Master or Slave | |
Function |
Communication interface with PCI Express and CANopen interfaceCC
|
|
Communication Controller | Type: netX 100 | |
Integrated Memory |
RAM: 8 MB SDRAM
FLASH: 4 MB serial Flash EPROM
MRAM: 128 Kbyte (= 64K Words)
|
|
Power Supply |
Supply voltage: +3.3 V DC ±5 %
Maximum current (typically): 800 mA (at 3,3 V)
Connector: via PCI Express Bus
|
|
System Interface |
Bus type: PCI Express, One Lane Port
Data access: DPM or DMA (Direct Memory Access)
Dual-port memory size: 64 KByte
Data width: 32-Bit
Transmission rate: 2 GBit/s
|
|
Communication Interface |
Communication standard: CANopen
Interface type: ISO-11898, optically isolated
Connector: D-Sub, male, 9-pin
Isolation voltage: 1000 V DC (tested for 1 minute)
|
|
Displays |
LED display
|
|
Operating Element | Rotary switch slot number (card ID): To set the slot number (card ID) | |
Permitted Ambient Conditions |
Operating temperature range: 0 °C ... +65 °C (Air flow during measurment: 0,5 m/s)
Storage temperature range: 0 °C ... +70 °C
Humidity: 10 % … 95 % relative humidity, no condensation permitted
|
|
Device | Dimensions (L x W x H): 119.0 x 69.0 x 18.5 mm | |
Configuration |
Configuration software for master and Slave: SYCON.net
Configuration software Slave: netX Configuration Tool
|
|
Conformity | RoHS: Yes | |
Conformance with EMC Directives |
CE sign: Yes
Emission: EN 55011:2009 + A1:2010, CISPR 11:2009, Class A (Radio disturbance characteristics - Limits and methods of measurement)
Immunity:
|