Part No.: MPHS-CIFX-50-CO+M (+Master License)
MPHS-CIFX-50-CO (Slave only)
CANopen-Master/ Slave: Communciation for PC-based Automation
The cifX PC card family is the unified standard supporting all Real-Time Ethernet and Fieldbus systems for PC based automation.
The protocol stack is executed autonomously on the PC card and process data exchange with the host is done via Dual-Port-Memory or DMA (Direct Memory Access). Thanks to the common Hilscher Platform Strategy all PC cards use the same driver and tools - independent of protocol and card format. Thanks to the netX technology there is exactly one hardware needed for the realization of all Real-Time Ethernet protocols. A change of the communication protocol is done by just loading a different firmware.
Always the right solution! Different cable lengths, M-12 connectors, additional NVRAM, extended temperature range, 2-channel cards or detached network interfaces – numerous hardware options always offer the right solution for your application. On top, a wide range of device drivers and a C-Toolkit, free of charge, are available.
The PC based automation is evolving and the Hilscher cifX PC card family keeps the pace. With continuous expansion for new standards, protocols and formats, as M.2, mini PCIe halfsize or CC-Link IE Field, customers are always prepared for new market demands.
Product | Product Name | CIFX 50-CO |
---|---|---|
Part Number | 1250.500 | |
Brief Description | PC Card cifX PCI CANopen Master or Slave | |
Function |
Communication interface with PCI and CANopen interface
|
|
Communication Controller | Type: netX 100 | |
Integrated Memory |
RAM: 8 MB SDRAM |
|
System Interface |
Bus type: PCI Transmission rate: 33 MHz Data access: DPM or DMA (Direct Memory Access) Data width: 32-Bit |
|
Communication Interface |
Communication standard: CANopen
Interface type: ISO-11898, optically isolated Isolation voltage: 1000 V DC (tested for 1 minute) Connector: D-Sub, male, 9-pin |
|
Power Supply |
Supply voltage: +3.3 V DC ±5 % Maximum current (typically): 650 mA Connector: Via PCI bus |
|
Displays |
LED display:
|
|
Operating Element | Rotary switch slot number (card ID): To set the slot number (card ID) | |
Permitted Ambient Conditions |
Operating temperature range: –20 °C ... +70 °C (Air flow during measurment: 0,5 m/s) Storage temperature range: –10 °C ... +70 °C Humidity: 10 % … 95% relative humidity, no condensation permitted Environment: For UL compliant usage: The device must be used in a pollution degree 2 environment. |
|
Device |
Dimensions (L x W x H): 120.0 x86 x 18.5mm (from hardware revisioin 5) Mounting/Installation: PCI slot (3,3 V) |
|
Conformity | RoHS: Yes | |
Conformance with EMC Directives |
CE sign: Yes Emission: EN 55011:2009 + A1:2010, CISPR 11:2009, Class A (Radio disturbance characteristics - Limits and methods of measurement)
Immunity:
|
|
UL Certification |
UL: The device is certified according to UL 508. UL file: UL-File-Nr. E221530 |
|
Configuration |
Configuration software for master and Slave: SYCON.net Configuration software Slave: netX Configuration Tool |