Gryphon S3
Part No: MPDG-CAN-S3-HERC
(with Hercules software)
Part No: MPDG-CAN-GRYPHON-S3
(hardware only)
註:此產品已由更強大的Gryphon-S4取代。
GRYPHON-S3套件是GM(通用汽車)所最新推薦的工具組合。現在的GRYPHON-S3已將無線連接及OBD-II cable列為標準配備。
該產品是一款超級CAN匯流排通訊協定分析工具。
GRYPHON-S3是通用汽車公司及其供應商的指定網路測試工具。它具有WIFI無線網卡,與該公司的匯流排分析軟體Hercules結合使用,被用于各種車內網路分析項目:動力系統(發動機和變速箱)的開發與調整測試、OBD2功能檢驗、可靠性驗證、匯流排利用率分析、匯流排資訊格式完整性分析和ALDL數據採集。Hercules支援CAN,
SW-CAN, Class2, LIN 協議和GMLAN診斷。該軟體有圖形顯示、即時(Real-time)數據顯示、熱鍵發送等多種功能。
GRYPHONE-S3硬體具有體積小,速度快的特點。它有一個擴充槽,可安裝其它需要的協議模組。另外,該產品內置32 MB RAM標準內存,和一個10/100T Ethernet 界面。其典型用戶包括通用汽車公司及其供應商。
所支援之通訊協定:
CAN (CAN Bus),
DeviceNet, GMLAN,
Honda, ISO9141-2, ISO11898 (CAN), ISO11992, ISO15765, J1850 GM (Class 2), J1850 Ford (SCP), J1850 DCX, J1939, J1979, J2284, J2411 (GM SW), J2534, KWP2000 (ISO14230), LIN, SCI - Chrysler, SWCAN, UBP.
For further use of the Gryphon S3 hardware only, the following protocols are available: KWP2000/ISO 9141, Ford J1850 (PWM, SCP), DCX J1850 (VPW), Fault-Tolerant CAN, and Honda UART.
Common Applications
|
Application |
Description |
Monitoring
Analysis
Diagnosis |
GRYPHON S3®
is also used as an interface for our Hercules CAN Analyzer software tool. Hercules is our
high performance Windows analyzer software with protocol support for CAN
(CAN Bus), GMLAN, ISO11898 (CAN), ISO15765, J1850 GM (Class 2), J1850
Ford (SCP), J1850 DCX, J1939, J1979, J2284, J2411 (GM SW), LIN and
SWCAN.
|
PV / DV
Interface
Analysis
Diagnosis
|
Included in test stand applications. |
Available Accessories and Options
The following items are available.
|
Part Number
|
Product Name
|
| MP-S3-CABLE |
OBD-II connector to the
Gryphon - S3’s DB-15 connector. |
| MP-OBDII-Y-CABLE
|
10" adapter cable with
one OBDII male connector and two OBDII female connectors. |
| MP-DB9-F04-CABLE
|
Four meter open-ended
cable with DB9 female connector. |
| MP-OBDII-BOX |
In-line breakout box to
J1962 connectors. |
| MP-GRYPH-LV |
GRYPHON
Labview Toolkit. |
Related Products
|
Part Number
|
Product Name
|
|
MP-GRYPH-2 |
GRYPH-2 – Gives You ethernet connection to in-vehicle networks with
protocol support for CAN (CAN Bus), DeviceNet, GMLAN, GMUART, Honda,
ISO9141-2, ISO11898 (CAN), ISO11992, ISO15765, J1850 GM (Class 2),
J1850 Ford (SCP), J1850 DCX, J1939, J1962, J2284, J2411 (GM SW),
J2534, KWP2000 (ISO14230), LIN, SCI - Chrysler, SWCAN and UBP. |
|
|
Gryphon S3 Tools
Software and Device Drivers
Note: These programs can be used with the Gryphon2, Gryphon S3,
Gryphon, S-CAT2 and S-CAT products.
Gryphon® Applications
-
Gryphon® Monitor
(GryphMON) - Version 1.92 – Used to monitor traffic on a
Gryphon®. This ZIP file also contains the GryphDB program.
-
GryphMON Manual – in html
format.
-
GryphDB Manual – in html
format. This product creates a database that gets imported
into GryphMon for message transmission.
-
Gryphon Scan Tool –
Utilizes Bonjour/ZeroConf networking to locate the IP
addresses of any Gryphons on your local subnet.
GryphSpeeds - Version 1.20 – A utility program that allows
the speed entries in gdevs file to be edited remotely.
-
GryphLIN - Version 1.12 –
Used to monitor LIN traffic on a Gryphon®.
-
GryphLIN Manual – in html
format.
-
GryphLIN Sample LDF –
Sample LIN definition file. Note: this is for example
purposes only, the required LDF will vary by implementation.
-
Gryphon LIN 2.0 Software:
Firmware, GRYPH_LIN monitor, Sample LDF, and more.
-
GM DPS Users^ Resources –
a collection of resources required to use the GM DPS
software.
Gryphon® C/C++ Libraries, Release 4.5
-
Win32 installer. – This
file installs the Gryphon® Libraries for use with C++, C and
VB applications. (EXE, 1947K) released 02/25/2110.
This release is for Win32 platforms only. It consists of the
file "setup.exe", which is a self-installer program. The
self-installer contains: the Release Notes document; the C
and C++ libraries, including dynamic link library files
(.DLL), header files (.H), and link support files (.LIB);
user manuals (.PDF); sample application program source and
project files; and a Visual BASIC module file. To
accommodate the use of Gryphon manifest constants in
application code, the latest header files for the Gryphon
protocol are also included in both packages.
See Release Notes for details of functional changes in the
libraries.
-
Missing DLL Help information.
– For customers who are unable to use the Gryphon®
C/C++ libraries (on Windows) due to "missing DLLs".
Note: In order to fix all bugs, this software may require a
firmware update. Contact Technical Support or your sales
representative for more information. Also see Gryphon®
firmware page.
Gryphon® EasyAPI Library
-
EasyAPI (J2534 DLL) -
Version 4.03 – This file contains a C-compatible interface.
Includes the API Library (with J2534 DLL), examples and Easy
API User Manual Version 1.0. The contents can be placed in
any file structure you prefer, but if not specified, creates
a new folder called "Gryphon" on your target drive, where
all files are installed.
EasyAPI User Manual Version 1.0.
NEW! Read about our new J2534 System Development Kit
(SDK)
GM User Alert: GM has validated this DLL to work with
DPS tools for Class 2.
Product Information
Product Data Sheet
-
Gryphon S3 Data Sheet.
-
Gryphon® / S-CAT Modules data sheet.
Product Manuals
-
Gryphon® - S3 Manual ; Version 1.0
-
Gryphon® Technical Information
-
How to connect Fault Tolerant CAN networks v2.0
-
Hercules Manual – Version 4
-
Hercules Application Note – Entering DPIDs in the Database
-
Gryphon® Networking Quick Start Guide – Version 1.0
Firmware
- Display Firmware information for Gryphon®2, Gryphon®, Gryphon® S3, S-CAT2, and S-CAT
Examples
- Display Hercules Examples and Tips.
- LIN 2.0 Card CPP Sample Code for a simple "send and receive" functionality.
- Adding External Voltage Transient Suppressors To the SCAT-2 and Gryphon - S3 on-board High Speed CAN Channels.
|
|